Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/88879
Título: Advantage of Beam Angle Optimization in Head-and-Neck IMRT: Patient Specific Analysis
Autor: Ventura, Tiago 
Lopes, Maria do Carmo Carrilho Calado Antunes 
Rocha, Humberto 
Ferreira, Brigida da Costa 
Dias, Joana
Palavras-chave: Radiation therapy; Beam angle optimization
Data: 2020
Editora: Springer
Título da revista, periódico, livro ou evento: IFMBE
Volume: 76
Resumo: Radiation therapy (RT) main purpose is to eliminate, in a controlled way, all tumor cells sparing as much as possible the normal tissues. Intensity-Modulated Radiation Therapy (IMRT) is becoming the standard treatment technique in RT. Beam angle optimization (BAO) has potential to confer more quality to IMRT inverse planning process compared to manual trial and error approaches. In this study, the BAO advantages in head-and-neck patients are highlighted, using a patient specific analysis. Fluence optimization was done with Erasmus-iCycle multicriterial engine and BAO optimization was performed using two different algorithms: a combinatorial iterative algorithm and an algorithm based on a pattern search method. Plan assessment and comparison was performed with the graphical tool SPIDERplan. Among a set of forty studied nasopharynx cancer cases, three patients have been select for the specific analysis presented in this work. BAO presented plan quality improvements when beam angular optimized plans were compared with the equidistant beam angle solution and when plans based on non-coplanar beams geometries were compared with coplanar arrangements. Improvement in plan quality with a reduced number of beams was also achieved, in one case. For all cases, BAO generated plans with higher target coverage and better sparing of the normal tissues.
URI: https://hdl.handle.net/10316/88879
ISBN: 978-3-030-31634-1
DOI: 10.1007/978-3-030-31635-8_153
Direitos: openAccess
Aparece nas coleções:I&D CeBER - Livros e Capítulos de Livros

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
MEDICON2019_paper_58.pdfAdvantage of Beam Angle Optimization in Head-and-Neck IMRT: Patient Specific Analysis716.87 kBAdobe PDFVer/Abrir
Mostrar registo em formato completo

Citações SCOPUSTM   

2
Visto em 14/out/2024

Citações WEB OF SCIENCETM
20

2
Visto em 2/nov/2024

Visualizações de página

365
Visto em 6/nov/2024

Downloads

434
Visto em 6/nov/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.