Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/4782
Título: Forensic intoxication with clobazam: HPLC/DAD/MSD analysis
Autor: Proença, Paula 
Teixeira, Helena 
Pinheiro, João 
Marques, Estela P. 
Vieira, Duarte Nuno 
Palavras-chave: Forensic intoxication; Clobazam; HPLC/DAD/MSD
Data: 2004
Citação: Forensic Science International. 143:2-3 (2004) 205-209
Resumo: Clobazam (Castillium®, Urbanil®), a benzodiazepine often used as an anxiolytic and in the treatment of epilepsy, is considered a relatively safe drug. The authors present a fatal case with a 49-year-old female, found dead at home. She had been undergoing psychiatric treatment and was a chronic alcoholic. The autopsy findings were unremarkable, except for multivisceral congestion, steatosis and a small piece of a plastic blister pack in the stomach. Bronchopneumonia, bronchitis and bronchiolitis were also diagnosed. Anhigh-performance liquid chromatography (HPLC)/diode array detector (DAD)/mass spectrometry detection (MSD) with electrospray method was developed in order to detect, confirm and quantify clobazam in the post-mortem samples. In the chromatographic separation, a reversed-phase column C18 (2.1×150 mm, 3.5 [mu]m) was used with a mobile phase of methanol and water, at a 0.25 ml/min flow rate. Carbonate buffer (pH 10.5) and 20 [mu]l of prazepam (100 [mu]g/ml) as internal standard were added to the samples. A simple and reliable liquid-liquid extraction method for the determination of clobazam in post-mortem samples was described. Calibration curves for clobazam were performed in blood, achieving linearity between 0.01 and 10 [mu]g/ml and a detection limit of 1.0 ng/ml. The clobazam concentration found in post-mortem blood was 3.9 [mu]g/ml, higher than the reported therapeutic concentration (0.1-0.4 [mu]g/ml). The simultaneous acquisition by photodiode array detection and mass spectrometry detection results allowed benzodiazepines to be identified with sufficient certainty.
URI: https://hdl.handle.net/10316/4782
DOI: 10.1016/j.forsciint.2004.03.029
Direitos: openAccess
Aparece nas coleções:FMUC Medicina - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
file6c3cb90225ed4560be72fa83929d7740.pdf105.69 kBAdobe PDFVer/Abrir
Mostrar registo em formato completo

Citações SCOPUSTM   

24
Visto em 28/out/2024

Citações WEB OF SCIENCETM

20
Visto em 2/nov/2024

Visualizações de página 20

714
Visto em 6/nov/2024

Downloads 50

539
Visto em 6/nov/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.