Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/4782
Title: Forensic intoxication with clobazam: HPLC/DAD/MSD analysis
Authors: Proença, Paula 
Teixeira, Helena 
Pinheiro, João 
Marques, Estela P. 
Vieira, Duarte Nuno 
Keywords: Forensic intoxication; Clobazam; HPLC/DAD/MSD
Issue Date: 2004
Citation: Forensic Science International. 143:2-3 (2004) 205-209
Abstract: Clobazam (Castillium®, Urbanil®), a benzodiazepine often used as an anxiolytic and in the treatment of epilepsy, is considered a relatively safe drug. The authors present a fatal case with a 49-year-old female, found dead at home. She had been undergoing psychiatric treatment and was a chronic alcoholic. The autopsy findings were unremarkable, except for multivisceral congestion, steatosis and a small piece of a plastic blister pack in the stomach. Bronchopneumonia, bronchitis and bronchiolitis were also diagnosed. Anhigh-performance liquid chromatography (HPLC)/diode array detector (DAD)/mass spectrometry detection (MSD) with electrospray method was developed in order to detect, confirm and quantify clobazam in the post-mortem samples. In the chromatographic separation, a reversed-phase column C18 (2.1×150 mm, 3.5 [mu]m) was used with a mobile phase of methanol and water, at a 0.25 ml/min flow rate. Carbonate buffer (pH 10.5) and 20 [mu]l of prazepam (100 [mu]g/ml) as internal standard were added to the samples. A simple and reliable liquid-liquid extraction method for the determination of clobazam in post-mortem samples was described. Calibration curves for clobazam were performed in blood, achieving linearity between 0.01 and 10 [mu]g/ml and a detection limit of 1.0 ng/ml. The clobazam concentration found in post-mortem blood was 3.9 [mu]g/ml, higher than the reported therapeutic concentration (0.1-0.4 [mu]g/ml). The simultaneous acquisition by photodiode array detection and mass spectrometry detection results allowed benzodiazepines to be identified with sufficient certainty.
URI: https://hdl.handle.net/10316/4782
DOI: 10.1016/j.forsciint.2004.03.029
Rights: openAccess
Appears in Collections:FMUC Medicina - Artigos em Revistas Internacionais

Files in This Item:
File Description SizeFormat
file6c3cb90225ed4560be72fa83929d7740.pdf105.69 kBAdobe PDFView/Open
Show full item record

SCOPUSTM   
Citations

24
checked on Oct 28, 2024

WEB OF SCIENCETM
Citations

20
checked on Nov 2, 2024

Page view(s) 20

714
checked on Nov 6, 2024

Download(s) 50

539
checked on Nov 6, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.