Title: Measurement of the refractive index and attenuation length of liquid xenon for its scintillation light
Authors: Solovov, V. N. 
Chepel, V. 
Lopes, M. I. 
Hitachi, A. 
Marques, R. Ferreira 
Policarpo, A. J. P. L. 
Keywords: Liquid xenon; Refractive index; Vacuum ultraviolet; Scintillation
Issue Date: 2004
Citation: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 516:2-3 (2004) 462-474
Abstract: The attenuation length and refractive index of liquid xenon for its intrinsic scintillation light ([lambda]=178 nm) have been measured in a single experiment. The value obtained for the attenuation length is 364±18 mm. The refractive index is found to be 1.69±0.02. Both values were measured at a temperature of 170±1 K.
URI: https://hdl.handle.net/10316/4453
DOI: 10.1016/j.nima.2003.08.117
Rights: openAccess
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais