Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/82111
Title: Avaliação da rugosidade superficial de resinas compostas com zircónia após polimento
Other Titles: Surface roughness evaluation of zirconia-based resin composites after polishing
Authors: Barros, Catarina Ferreira 
Orientador: Vinagre, Alexandra Rosa Rodrigues
Fonseca, Ana Sofia Domingos Chambino Silva
Keywords: rugosidade superficial; resinas compostas; acabamento; polimento; surface roughness; resin-based composites; finishing; polishing
Issue Date: 21-Jul-2017
metadata.degois.publication.title: Avaliação da rugosidade superficial de resinas compostas com zircónia após polimento
metadata.degois.publication.location: FMUC
Abstract: Objetivo: O objetivo deste estudo foi avaliar a rugosidade superficial de resinas compostas com zircónia após polimento.Materiais e métodos: Os materiais avaliados foram: Zirconfill® (TECHnew, RJ, Brasil), Filtek™ Supreme XTE (3M ESPE, St Paul, MN, USA), Brilliant EverGlow™ (Coltène, Whaledent, Altstätten), Ceram.X® Duo (Dentslpy, Middle East & Africa), e Harmonize™ (KERR, Orange, CA, USA). Foram executadas 10 amostras por grupo, tendo sido utilizado um molde circular de silicone com 6 mm de diâmetro e 1,5 mm de espessura. As superfícies das amostras foram inicialmente preparadas com discos abrasivos de carboneto de silício de granulometria 1200 em ambiente humedecido, em ambos os lados e durante 5 segundos cada de forma a uniformizar a superfície das amostras. De seguida apenas uma superfície de cada amostra foi sujeita a um sistema de polimento SwissFlex® Disc (Coltene, Cuyahoga Falls, OH, USA), numa sequência de granulometria decrescente (70 μm > 50μm > 30μm > 5μm), com rotação standardizada a 7500 rpm. Após o polimento avaliou-se a rugosidade superficial (valor Sa–μm) de todas as amostras de cada grupo. Foi utilizado um perfilómetro ótico 3D sem contato (S neox® 3D, Sensofar, Stuttgart, Alemanha). A análise estatística foi realizada com o programa IBM® SPSS® Statistics Version 23. A avaliação de diferenças entre cada par de grupos foi corrigida através do método de Bonferroni. O nível de significância foi estabelecido em 0.05 para todas as análises.Resultados: Encontraram-se diferenças estatisticamente significativas entre a rugosidade superficial das diferentes resinas compostas estudadas (p<0.05). Brilliant EverGlow™ e Ceram.X® Duo apresentam as rugosidades médias de menor valor; Harmonize™ uma rugosidade média de valor intermédio; Zirconfill® e Filtek™ Supreme XTE apresentaram os valores mais elevados de rugosidade média superficial.Conclusão: Dentro das limitações do presente estudo, as cinco resinas compostas testadas apresentaram diferenças estatisticamente significativas nos valores médios de rugosidade superficial (Sa) após procedimentos de polimento.
Objective: The aim of this study was to evaluate the surface roughness of zirconia-based resin composites after polishing.Methods: The materials evaluated were: Zirconfill® (TECHnew, RJ, Brasil), Filtek™ Supreme XTE (3M ESPE, St Paul, MN, USA), Brilliant EverGlow™ (Coltène, Whaledent, Altstätten), Ceram.X® Duo (Dentslpy, Middle East & Africa), and Harmonize™ (KERR, Orange, CA, USA). Ten specimens of each composite were made using a circular silicone mold with 6 mm of diameter and 1,5 mm of thickness. The surfaces of the samples were initially prepared with 1200 silicon carbide abrasive disks in a humidified environment, on both sides and for 5 seconds each in order to standardize sample surfaces. Then, only one surface of each sample was subjected to a SwissFlex® Disc polishing system (Coltene, Cuyahoga Falls, OH, USA), in a decreasing granulometry sequence (70 μm > 50μm > 30μm > 5μm), with rotation set at 7500 rpm. After polishing the surface roughness was evaluated (Sa-μm value), of all samples from each group. A non-contact 3D optical profilometer was used (S neox® 3D, Sensofar, Stuttgart, Alemanha). Statistical analysis was performed with the IBM® SPSS® Statistics Version 23. The evaluation of differences between each pair of groups was corrected by the Bonferroni method. The level of significance was established at 0.05 for all analysis.Results: There were statistically significant differences between the surface roughness of the different composite resins studied (p<0.05). Brilliant EverGlow™ and Ceram.X® Duo obtained the lowest values of roughness; Harmonize ™ an intermediate value; Zirconfill® and Filtek ™ Supreme XTE showed the highest values of surface roughness.Conclusion: Within the limitations of the present study, the five composite resins tested presented statistically significant mean values of surface roughness (Sa) after polishing procedure.
Description: Trabalho de Projeto do Mestrado Integrado em Medicina Dentária apresentado à Faculdade de Medicina
URI: https://hdl.handle.net/10316/82111
Rights: embargoedAccess
Appears in Collections:UC - Dissertações de Mestrado

Files in This Item:
File Description SizeFormat
TESE DE MESTRADO CATARINA BARROS.pdf1.03 MBAdobe PDFView/Open
Show full item record

Page view(s) 50

622
checked on Nov 6, 2024

Download(s) 50

394
checked on Nov 6, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons