Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/47898
Title: An integrated energy performance-driven generative design methodology to foster modular lightweight steel framed dwellings in hot climates
Authors: Rodrigues, Eugénio 
Soares, Nelson 
Fernandes, Marco S. 
Gaspar, Adélio Rodrigues 
Gomes, Álvaro 
Costa, José J. 
Keywords: Generative building design; Building performance optimization; Dynamic Simulation; Energy Efficiency
Issue Date: 2018
Publisher: Elsevier; Published on behalf of the International Energy Initiative
Project: Ren4EEnIEQ (PTDC/EMS-ENE/3238/2014, POCI-01-0145-FEDER-016760, LISBOA-01-0145-FEDER-016760) 
PCMs4Buildings - Sistemas com cavidades rectangulares com materiais de mudança de fase para o aproveitamento de energia solar térmica em edifícios 
SFRH/BPD/99668/2014 
metadata.degois.publication.title: Energy for Sustainable Development
metadata.degois.publication.volume: 44C
Abstract: This paper presents a study on the application of lightweight steel framed (LSF) construction systems in hot climate. A generative design method created 6010 houses, with random geometry and random roof and exterior wall types with different insulation levels, and EnergyPlus was used to evaluate the energy consumption for air-conditioning of each building. The main goals were to determine which geometric variables correlate with the energy performance, and to provide some guidelines to foster efficient LSF buildings in hot climates. By correlating six geometry-based indexes with the energy consumption for each construction element type group, it was verified that roofs do not show significant correlation, while exterior walls presented weak to moderate positive correlation with the building volume, very weak to weak negative correlation with the relative compactness, no correlation with the shape coefficient, moderate to strong negative correlation with the window-to-floor, window-to-wall, and window-to-exterior surface ratios. The results also show that buildings with larger windows and greater level of insulation have better energy performance. No significant difference of energy performance was found between different LSF construction systems with equivalent thermal resistance.
URI: https://hdl.handle.net/10316/47898
ISSN: 0973-0826
DOI: 10.1016/j.esd.2018.02.006
Rights: openAccess
Appears in Collections:FCTUC Eng.Mecânica - Artigos em Revistas Internacionais

Files in This Item:
File Description SizeFormat
LSF_EPSAP_BPS_manuscript.pdf25.06 MBAdobe PDFView/Open
Show full item record

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons